Varunummer: 2759935

Elma Instruments Elma easy-iso insulation adapter

When you make an insulation test on curcuits with elektronical equipment included, you should connect all phases and neutral together, during the measurement. In this way you are shure about, that there will be no potential between the leads, and therefore you will avoid accidents with electronical equipment and sensitive equipment. With the new Easy-ISO it is even more easy to make above written connections, and then make the measurement. Easy-ISO includes four Ø6,6 mm magnetical probes and a 4-pole test lead, which is connected together as one test lead. The magnetical probes are holding the wire fixed automatically on the measuring point, not using any other helping tools. An insulation test is made on an installation with no voltage present. Disconnect eg. on the RCD and connect the Easy-ISO on the downstream on a 4-pole curcuit breaker. If all the groups on the curcuit breaker is on, then you normally is able to measure the hole installation at once. Using this method all the installation is shortedit is important to disconnect Easy-ISO, before turning on the voltage. Elma Easy-ISO leveres i lille taske og opfylder IEC 61010-1 KAT III 600V. Technical data: Current: max 2A IEC61010: Cat III 600V

I lager
850,00 kr 680,00 kr exkl. moms
Billigaste frakt: 49,00 kr
2 st. I lager, 1-2 vardagars förväntad leveranstid

Isolation adapter with magnets Product description: When testing circuits containing electronics for isolation, all phase and neutral conductors should be connected together during the measurement. This ensures that there is no potential between the conductors and prevents accidents with electronics and sensitive equipment. With the new Easy-ISO, it has now become very easy to make these connections and perform the measurement. The Easy-ISO set consists of four Ø6.6 mm magnetic probes and a 4-pole cable, which are assembled in a measuring bushing. With magnetic probes, the cable automatically attaches to the measuring point without using tools or loosening clamps.Isolation testing is performed on voltage-free installations. For example, disconnect at the residual current device (RCD) and mount Easy-ISO on the output side of a 4-pole circuit breaker group switch. If all groups are turned on, you can now normally measure the entire installation at once. Since this method has short-circuited installation, it is important to remove Easy-ISO before reconnecting power supply.Elma Easy-ISO comes in a small bag and meets IEC 61010-1 CAT III 600V.TECHNICAL DATA Current: max 2A Technical specifications: AC current: 2ASize: Ø6mm

Producent
Varunummer
2759935
Modell
5706445320769
EAN
5706445320769

Ovanstående information och specifikationer är vägledande och kan utan förvarning ändras av producenten. Alla uppgifter lämnas med reservation för tryckfel, och bilder är vägledande. Vissa texter kan vara autogenererade eller maskinöversatta och kan därför ge texter som kan vara missvisande.