Varunummer: 2371212

APC Metered Rack PDU AP8886

Kraftdistributionsenhet ( kan monteras i rack ), AC 400 V, Ethernet, RS-232, USB, 42 Utgång(ar), 0U

34 221,00 kr 27 376,80 kr exkl. moms
Billigaste frakt: 20,00 kr
Leverantör, 3-4 vardagar leveranstid

APC Metered Rack Power Distribution Units (PDUs) provide active metering to enable energy optimization and circuit protection. User-defined alarm thresholds mitigate risk with real-time local and remote alerts to warn of potential circuit overloads. Metered Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers.

Producent
Varunummer
2371212
Modell
AP8886
EAN
0731304289937
Till producentens hemsida
Produktbeskrivning
APC Metered Rack PDU - kraftdistributionsenhet
Typ av enhet
Kraftdistributionsenhet - kan monteras i rack
Stativstorlek
0U
Vikt
8.72 kg
Ingångskablage
3-fas
Inspänning
AC 400 V
Utspänning
230 V
Inmatningsanslutningar
1 x ström IEC 60309 32A
Utdatakontakter
30 x power IEC 60320 C13
12 x ström IEC 60320 C19
Nätverk
Ethernet, RS-232, USB
Protokoll för administration på distans
SNMP, Telnet, HTTP, SSH
Färg
Svart
Dimensioner (BxDxH)
5.6 cm x 5.1 cm x 182.9 cm
Designat för
P/N: AR3103SP, AR3106SP, AR3357X674, SMX1000C, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2KR2UX145, SMX3000LVUS, SMX3000RMLVUS, SMX3KR2UNCX145, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750CUS, SMX750US, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10RMXLIX806, SRT5KRMXLTUS, SRT5KRMXLW-TW

Allmänt

Typ av enhet
Kraftdistributionsenhet - kan monteras i rack
Höjd (U-format)
0U
Färg
Svart

Nätdel

Inspänning
AC 400 V
Ingångskablage
3-fas
Erforderlig frekvens
50/60 Hz
Inmatningsanslutningar
1 x ström IEC 60309 32A
Kontaktdetaljer för uteffekt
30 x power IEC 60320 C13
12 x ström IEC 60320 C19
Utspänning
230 V
Max elektrisk ström
32 A
Kretsskydd
Strömbrytare

Nätverk

Gränssnitt för fjärradministration
Ethernet, RS-232, USB
Protokoll för administration på distans
SNMP, Telnet, HTTP, SSH

Expansion/Anslutning

Gränssnitt
1 x hantering (Ethernet) - RJ-45
1 x seriell
1 x USB

Diverse

Medföljande kablar
Strömkabel 1.8 m
Seriell kabel - extern
Rackmonteringssats
Inkluderat
Egenskaper
LCD-bildskärm, spänningsmätare, överspänningsskydd, överbelastningsskydd
Standarder som följs
EN 61000-3-2, ICES-003, VDE, VCCI klass A ITE, EN 61000-3-3, EN55024, EN55022 klass A, RoHS, FCC Part 15 A, REACH

Miljöparametrar

Min temperatur vid drift
0 °C
Max temperatur vid drift
50 °C
Luftfuktighet vid drift
5 - 95%

Mått och vikt

Bredd
5.6 cm
Djup
5.1 cm
Höjd
182.9 cm
Vikt
8.72 kg

Mått och vikt (brutto)

Emballagets bredd
17 cm
Emballagets djup
12 cm
Emballagets höjd
205 cm
Emballagets vikt
11.6 kg

Kompatibilitetsinformation

Designat för
P/N: AP7950B, AR2200, AR2280, AR2400, AR2400FP1, AR2401, AR2407, AR2480, AR2487, AR2487G, AR2500, AR2507, AR2580, AR2587, AR3100G, AR3100TAA, AR3100W, AR3100X609, AR3100X610, AR3100X617, AR3103SP, AR3105, AR3105SP, AR3105W, AR3106SP, AR3107G, AR3107SP, AR3107X609, AR3107X610, AR3107X617, AR3140G, AR3140W, AR3150SP, AR3150W, AR3150X609, AR3150X610, AR3150X617, AR3155, AR3155SP, AR3155W, AR3157SP, AR3157X609, AR3157X610, AR3157X617, AR3180G, AR3300G, AR3300SP, AR3300W, AR3300X609, AR3300X610, AR3300X617, AR3305, AR3305SP, AR3305W, AR3307SP, AR3307W, AR3307X609, AR3307X610, AR3307X617, AR3340G, AR3340W, AR3350SP, AR3350W, AR3350X609, AR3350X610, AR3350X617, AR3355, AR3355SP, AR3355W, AR3357SP, AR3357X609, AR3357X610, AR3357X617, AR3357X674, NBES0302, NBPD0160A, NBPD0180, NBWL0355A, NBWL0356A, SMC1000, SMC1000-2U, SMC1000-BR, SMC1000I, SMC1000I-2U, SMC1000I-2UC, SMC1000I-BR, SMC1000IC, SMC1500, SMC15002U-BR, SMC1500-BR, SMC1500I, SMC1500I-2U, SMC1500I2U-BR, SMC1500I-2UC, SMC1500I-BR, SMC1500IC, SMC2000I-2U, SMC3000RMI2U, SMT1500RM1U, SMT1500RM2U, SMT1500RMI1U, SMT2200R2X658, SMT2200RM2UC, SMT3000I2U-BR, SMT3000RM2UC, SMX1000C, SMX1000US, SMX1500RM2UC, SMX1500RM2UCNC, SMX1500RMNCUS, SMX1500RMUS, SMX2000LV, SMX2000LVNC, SMX2000LVNCUS, SMX2000LVUS, SMX2200HV, SMX2200HVNC, SMX2200R2HVNC, SMX2200RMHV2U, SMX2200RMLVUS, SMX2KR2UX145, SMX3000HV, SMX3000HV-BR, SMX3000HVNC, SMX3000HVT, SMX3000HVTUS, SMX3000LV, SMX3000LV2U-BR, SMX3000LVNC, SMX3000LVNCUS, SMX3000LVUS, SMX3000RMLVUS, SMX3KR2UNCX145, SMX3KRMLVNCUS, SMX750C, SMX750CNC, SMX750CUS, SMX750-NMC, SMX750US, SRT1000RMXLA, SRT1000RMXLA-NC, SRT1000RMXLI, SRT1000RMXLI-NC, SRT10KRMXLI, SRT10RMXLIX806, SRT1500RMXLA, SRT1500RMXLA-NC, SRT5KRMXLT, SRT5KRMXLT-IEC, SRT5KRMXLTUS, SRT5KRMXLW-HW, SRT5KRMXLW-TW, SRT6KRMXLI, SRT6KRMXLT, SRT6KRMXLT-IEC, SRT8KRMXLI, SRT8KRMXLT, SRT8KRMXLT-IEC, SURT3000XLI-ET, SURT5000XLIX438, SYA12K16RMICH, SYA8K16RMICH, SYAF16KRMICH, SYAF8KRMTX424

Ovanstående information och specifikationer är vägledande och kan utan förvarning ändras av producenten. Alla uppgifter lämnas med reservation för tryckfel, och bilder är vägledande. Vissa texter kan vara autogenererade eller maskinöversatta och kan därför ge texter som kan vara missvisande.